Application of Uncertainty evaluation to Verification of Measuring Apparatus for Dust Content in Stack;
测量不确定度在烟尘测试仪检定中的应用
Verification of filtering characteristics for measuring system of roundness measuring instrument;
圆度仪测量系统滤波特性的检定
Verification of standard voltage for ECG & EEG verification instrument with 34401A;
用34401A检定心脑电图机检定仪的定标电压
An analysis of the SATAM type on-line flowmeter calibration equipment;
SATAM型现场流量计检定装置的分析
Fault treatment and calibration of universal material testing machine;
材料试验机故障调修与检定
Discussion on Standards for Calibration of Universal Tensile Testing Machine;
万能拉力试验机检定标准的研讨
Detection of VO_3~- by using promethazine;
异丙嗪与离子的反应及其用作VO_3~-检定的研究
Chlorpromazine as a new inorganic analytical agent—rapid microdetection of bismuth (Ⅲ);
氯丙嗪用于微量铋(Ⅲ)离子的快速检定
Based on the detection rules of Y802 oven, it makes a supplement to it and puts forward a detailed detection operating sequence.
本文指出了《JJG- 0 70 - 1 999纺织通风式烘箱计量检定规程》存在的问题 ,并根据作者多年的工作经验 ,在借鉴 Y80 2型烘箱检定规程的基础上 ,对其进行了补充、完善 ,提出了比较详尽的检定操作程序。
The analysis and troubleshooting of examination unqualified reason in mercury sphygmomanometer;
汞柱式血压计检定不合格的原因分析及故障排除
This text introduces how to upgrade and rebuild the existing humidity examination system that the province and city scene humidity department has disposed and introduces how to make the system be- come a digital and automatic one.
主要介绍了如何对省、市气象计量检定部门原来配置的湿度检定系统进行升级改造,使之成为数字化自动化检定系统。
This thesis analyses causes of errors of the theodolite examination.
分析了光学经纬仪检定方法中产生的误差的来源和大小。
A Study on the measurement and test of the biochemical analyzer;
生化分析仪计量检定的研究
In this paper, the principles, uncertainty analyses and test results of calibration devices for water oil content analyzer is described.
该装置用于检定和校验各种水份测试仪器。
This paper introduces briefly how to propagate the measurement law of the military medical measurement station, how to enlarge the area applied medical measurement, how to test and manage the medical measurement units.
本文扼要介绍了做好军队医学计量二级站的计量法宣传教育 ,扩大医学计量覆盖面 ,做好医学计量器具的检定和使用管理工作的经验和体
The components of the uncertainty of verification result were evaluated and calculated.
依据JJG548-2004对冷原子荧光测汞仪进行检定时,检定结果的不确定度主要来源于仪器的线性误差、检测限、重复性和标准物质浓度。
Though expounding the different measuring methods for the heat treating furnace,this paper analyzes on the reasons why the component detection can't satisfy the technical requirement,points out the problems existing in adopting the component detection method for the heat treating furnace,and expounds the advantages of the integral calibration on the heat treating furnace.
通过简述热处理炉的不同测量方法,分析了分量检定不能满足工艺要求的原因,指出了对热处理炉采用分量检定法存在的问题,阐明了对热处理炉进行整体校准的优越性。
Copyright © 2022-2024 汉字大全www.hanzidaquan.com All Rights Reserved 浙ICP备20019715号