Objective An acidic electrolyzed oxidizing water disinfecting system used for the disinfection of hemodialysis machine was researched to observe the disinfecting efficacy.
目的研究血液透析机用酸性氧化电位水消毒系统,观察其消毒效果。
Analyzes "V84 failure" occurring in Fresenius hemodialysis machine with the self-diagnosis program provided by the machine.
对费森尤斯血液透析机出现的"V84 failure"故障,用该机自我诊断程序进行了分析,结果表明故障系所用自配柠檬酸消毒液絮状物堵塞残留阀门所致,比较了两种处理方法的效果,并提出了预防措施。
Describes an improvement design combining the temperature transducer DS18B20 with AVR single chip and puts forward the improvement using the temperature transducer of Toray TR321EX hemodialysis machine.
本文针对东丽TR321EX血液透析机温度传感器设计上的不足,提出使用温度传感器DS18B20和AVR单片机对其进行改进。
Working principle of air bubble detector in NIPRO dialyzer;
NIPRO血液透析机血液回路气泡检测器的工作原理
The general situation of the dialyzer and the points for attention;
血液透析机概况及应注意的问题
Analysis of the water-flow chart of JMS SDS-20dialyzer;
JMS SDS-20血液透析机水路流程分析
Puts forward that the different measures should be taken for the same failures of Fresenius hemodialysis system according to the concrete problems in the maintenance.
通过费森尤斯血液透析机相同故障现象而不同故障原因的实例,提示维修人员要针对具体问题采取不同的维修措施。
This paper describes the basic principle of hemodialysis system,also analyses and classifies the common failures of hemodialysis system.
本文阐述了血液透析机的基本工作原理。
Effects of Astragalous Injection on oxidative stress status in maintenance hemodialysis patients;
黄芪对血液透析患者氧化应激的影响
Analysis of Nutrition Condition and Nursing Method for Hemodialysis Patients with Helicobacter Pylori Infection;
幽门螺杆菌感染血液透析患者营养状况分析及护理对策
A Study on Depression and its Related Factors in Hemodialysis Patients;
血液透析患者的抑郁发生及其相关因素研究
Relationship Between Hemodialysis Dialysate Circuit Functions and Dialysis Quality
血液透析机透析液回路的功能与透析质量的关系
Two Cases of Troubleshooting for Fresenius 4008S Hemodialysis System
费森尤斯4008S血液透析机故障维修两例
Solution for inaccurate dehydration of DBB-26 hemodialysis machine
日机装DBB-26血液透析机脱水不准的维修
Failure Analysis and Troubleshooting of Gambro AK95 Hemodialysis System
金宝AK95血液透析机自检故障分析和维修
Principle and Malfunction Analysis for the Fresenius Hemo Dialysis Machine of Balance Chamber System
Fresenius血液透析机平衡腔系统工作原理及故障分析
Question which needs to pay great attention about in the blood dialysis machine maintenance and the management
关于血液透析机维护和管理中需要注重的问题
Prolongation of service life of Bellco haemodialysis machine concentrate pump by modifying preset
修改设置延长贝尔克血液透析机浓缩液泵使用寿命
Nursing Intervention for Phosphate Pesticide Poisoning Patients Received Hemoperfusion and Hemodialysis
血液灌流联合血液透析治疗有机磷中毒的护理
Comparing the Fect of High-Flux Hemodialysis, Convention Hemodialysis and Hemodiafiltration;
高通量血液透析与常规血液透析、血液透析滤过的透析效果比较
Effects of dialysate flow rate on dialysis adequacy in patients with maintenance hemodialysis
透析液流量对血液透析充分性的影响
Clinical Study of Clearance of β_2-Microglobulin by On-line Hemodiafiltration with Single Pump Hemodialysis Machine
单泵血透机on-line血液透析滤过技术清除β_2-微球蛋白的临床研究
Analysis of breakdowns and their solutions of NIKKISO DBB-26 hemo-dialysis apparatus
日机装DBB-26血液透析装置故障分析与处理
Observation of effects of hemoperfusion associated with hemodialysis on severe organophosphorous poisoning
血液灌流加血液透析抢救重症有机磷农药中毒疗效观察
The Mechanism of Hemodialysis Catheter-related Infections
血液透析深静脉留置导管相关性感染机制研究
The Discussion of High-flux Hemodialysis and Conventional Hemodialysis Efficacy
高通量血液透析与常规血液透析的疗效探讨
The Nursing of the Combined Treatment by HP and HD;
血液灌流与血液透析联合治疗的护理
Hemodialysis maintain the dialysis adequacy in peritoneal dialysis patients
血液透析对腹膜透析患者透析充分性的支持
Hemodialysis can rectify uraemia patients bleeding tendency through improving the platelet activation function,hemodialysis can help to resume the immunity in uraemia patients.
血液透析通过改善血小板活化功能来纠正尿毒症性出血倾向 ,血透有助于机体的免疫力的恢复。